Hog 86 product overview – Baumer HOG86 User Manual

Page 6

Advertising
background image

Baumer Group
International Sales
P.O. Box · Hummelstrasse 17 · 8501 Frauenfeld
Phone +41 52 728 1122 · Fax +41 52 728 1144
[email protected] · www.baumer.com

HOG 86 T

HOG 86 F

HOG 86 K

HOG 86 M

HOG 86 L

HOG 86 ML

Sensing method

Optical

Voltage supply
and
output circuit

5 VDC ±5 %, TTL/RS422, max. 500 m

9 ... 30 VDC, TTL/RS422, max. 500 m

9 ... 30 VDC, HTL/push pull, max. 300 m

9 ... 30 VDC,

LWL1,

LWL2 redundant,

max. 1500 m

9 ... 30 VDC, LWL1,

LWL2 redundant,

max. 1500 m

9 ... 30 VDC, TTL/

RS422, max. 500 m

9 ... 30 VDC,

HTL/push pull,

max. 300 m

Output signals

K1, K2, K0 and inverted / Error output (only with EMS)

Shaft

Non-through hollow shaft, ø12 mm or 16 mm

Cone shaft 1:10, ø 17 mm / Shaft material: stainless steel

Connection

Terminal box

rotatable through

180°

M23-

connector outlet

Cable outlet

2 x terminal box

(redundant sensing

and signal output)

Terminal box

with fi ber-optic

interface

Terminal box with

2 redundant fi ber

optic outputs and

terminal box rota-

table through 180°

for HTL/TTL signal

Pulses per revolution

500 ... 2500

Operating tempe-
rature

-40 ... +100 °C

-40 ... +80 °C

-40 ... +100 °C

-20 ... + 70 °C

Operating speed

≤10000 (mechanical)

Protection class

IP 66

Insulated bearings /
hybrid bearings as
an option
EMS

Optional

Approvals

CE, UL, CSA

CE, UL

Ex protection

II3G Ex nA T4 X (gas), II3D Ex tD IP 66 A22 T135 °C (dust)

HOG 86 product overview.

More product information on our HeavyDuty encoders is available for download under

www.baumer.com/HOG86 or will be gladly provided by our encoder experts. Contact us.

Find your local partner:

www.baumer.com/worldwide

Subject to modifi

cation in technic and design.

08/13 No. 11113807

HOG 86 ML

HOG 86 T

HOG 86 F

Advertising