Mounting your extractor

6. When used with a CDA hob, the extractor is required

to be 650mm above the hotplates. Measure the height

of the ceiling and then the hotplate height from the floor.

The length of the support sections should be calculated

as follows: -

Length of support = Ceiling height – (149 + 650 + Hotplate
height)

Note that if the exact height cannot be set, use the
frame position corresponding to the next highest one.

7. Fit the lower section (B) to the upper section (C) at the

correct height and secure in position using the supplied

screws (G)

8. Refit (If required) and secure the motor body to the

lower section and secure with the supplied screws.