EPIM Specifications

CSX400 and CSX400-DC User’s Guide

221

EPIM-C

The EPIM-C supports thin coaxial cabling and is equipped with an internal Cabletron Systems
TMS-3 Transceiver. You can use the TERM switch on the front of the EPIM-C to set the internal
50-ohm terminator. This eliminates the need to connect the port to a T-connector and terminator.

Figure 81

shows the setting for the terminator switch.

Figure 81

EPIM-C

Connector Type

This connector type is a BNC receptacle with gold center contact for use with BNC type
T-connectors and RG58 coaxial cable.

Grounding

The BNC port of the Coaxial Interface Modules is not connected to earth ground.

!

CAUTION

For safety reasons, only one end of a coaxial segment should be connected to earth
ground. Connection to earth ground at more than one point on the segment may
cause dangerous ground currents.

Internal Termination Switch
= On (internally terminated)
= Off (need external termination)