Plan the Ductwork

This downdraft blower system is designed for use with 3¼

x 10” ductwork (can be transitioned to 6” round).
For best performance, choose the ducting option which

allows the shortest length of ductwork and a minimum

number of elbows and transitions.
The system will operate most efficiently when the ductwork

does not exceed 60 feet of equivalent duct. The downdraft

will operate properly with ductwork up to 100 equivalent feet

of duct. See page 12 for Calculated Duct Length Table.

PLANNING

The blower can be mounted to the vent chassis housing to

provide exhaust discharge down, as supplied (Fig. 1), or

90° to the left (Fig. 2) or 90° to the right (Fig. 3). Position

the blower before installing the vent chassis housing in the

countertop.

Plan the Discharge

Fig. 1 - Discharge down (as supplied)

Fig. 2 - Discharge left

Fig. 3 - Discharge right

Slide Plate

Adjustment

Use the 2

outermost

screw holes

for the blower

slide plate.

Hex Head Screw

Inner

Hole

NOTE

For left or right discharge, the blower housing needs to

be rotated for proper venting. See page 9 for instructions

on rotating the blower.

The blower is mounted on a slide plate which may be

adjusted 3½” (8.9cm) left or right to help avoid duct

interference with joists or other obstructions. To adjust the

slide plate, loosen the 2 hex head (¼” driver) screws and

move the slide plate to the desired position and tighten

the screws.

CAUTION

To reduce risk of fire and to properly exhaust air, be sure

to duct air outside – Do not vent exhaust air into spaces

within walls or ceilings or into attics, crawl spaces, or

garages.