Abbingdon Music Research CD-77 Reference Class User Manual

Page 13

Advertising
background image

13

3.1 Power On/Off

Use the rocker ‘POWER’ switch (R6) at the rear of the CD-77 to switch mains power ON to the CD-77.

To switch the mains power OFF, press again and release. Always WAIT at least 30 seconds before switching on
again. This is to enable the OptiMains® circuit to shutdown properly.

The display will light up to indicate the unit is switched on and ready for use. This should take just under 1 minute
as the OptiMains® circuit is verifying the incoming mains and the CD processor is warming up.

3.2 Standby

After start-up, pressing the STANDBY button on either the front panel (F1) or the RC-77 (RC5), the CD-77 will
switch to STANDBY mode.

Standby

By pressing either of these buttons again, the CD-77 will commence warm-up to prepare for operation.

Under STANDBY mode, power to CD-77’s digital circuit is kept active in order to provide the optimum perform-
ance for the next listening session. However, power to the valves will be switched off to preserve valve life.

Standby will maintain

power to the non-

valve circuitry

Once powered OFF:

always wait 30

seconds before

switching on again

Section 3 - Operation

Advertising