Troubleshooting, Caution – Century INVERTER ARC IM10008 User Manual

Page 21

Advertising
background image

E-2

TROUBLESHOOTING

E-2

INVERTER ARC™ 230

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Excessive spatter

Craters

Inclusions

Insufficient penetration

Electrode Sticking

Porosity

Cracks

1. Improper welding polarity.

2. Long Arc Length.

3. High Current.

1. Fast movement of the electrode

away from the work piece.

1. Poor cleanliness.

2. Poor distribution of the welding

passes.

1. High travel speed.

2. Welding current is too low.

1. Arc length is too short.

2. Welding current is too low.

1. Humidity in the electrode.

2. Long arc length.

1. Weld current is set too high.

2. Dirty materials.

3. Hydrogen in the weld due to mois-

ture.

1. Make sure the electrode holder is

plugged into the positive “+” out-
put terminal.

2. Move the electrode closer into the

weld joint.

3. Turn the output knob down.

1. Maintain a steady consistent arc

length

1. Clean work piece with wire brush

prior to welding.

2. Consult a welding guide for proper

weld bead placement.

1. Travel at a slower speed.

2. Adjust welding output higher.

1. Move the electrode further away

from the weld joint.

2. Turn the output knob up.

1. Store welding electrodes in a

warm dry place.

2. Move the electrode closer into the

weld joint.

1. Turn the output knob down.

2. Clean work piece with wire brush

prior to welding.

3. Store welding electrodes in a

warm dry place.

WELDING PROBLEMS

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Advertising