TROUBLESHOOTING

E-3

INVERTER ARC™ 230

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine fails to come on

(Power LED off)

Thermal overload

(Thermal LED on)

The fan works, but the output current
is unstable and can not be controlled
by the potentiometer while welding is
carried out.

1. No Input Voltage.
2. Faulty supply plug or cable.
3. Supply fuse blown or breaker

tripped.

1. Unit has been operated beyond its

capacity rating.

2. Airflow through machine is restrict-

ed or fan has failed.

1. Check the output current poten-

tiometer, and replace it if neces-
sary.

2. Verify output cables are attached

to the welder and tightly connect-
ed.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Authorized Field
Service Facility.

ELECTRICAL FAILURES

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Advertising