- With the gate in the CLOSED position, mount the origin marker (66) a minimum
500mm from the origin sensor (68). (See isometric view (A) or plan view (B)
above).Please note this distance will affect the pedestrian opening distance. For

minimum pedestrian opening, mount the origin marker at 500mm. The

maximum distance of the origin marker is limited by the marker having to pass
the sensor by no less than 500mm before the gate opens fully. If a longer
crawling distance is required, the position of the marker needs to be changed
(see table 3 on page 30).

- Manually slide gate OPEN until origin marker (66) is in line with the origin

sensor (68). Ensure distance between face of marker (66) and front face of
sensor (68) is between 13 and 20mm. (See (C) above)

- Adjust distance by sliding the origin marker (66) along the slotted mounting
holes until desired distance is achieved.

MOUNTING OF GATE SENSOR

66

B

C

C

A

66

68

R

TE

TH

AN

5

0m

m

G

EA

R

0

MOUNTING CONFIGURATION

FOR STEEL RACK

ORIGIN MARKER

BRACKET

WELD

MOUNTING

BRACKET

PROVIDED TO

STEEL RACK

BOLT USING

FASTENERS

PROVIDED

66

66

13-20mm

GREATER THAN 500mm

68