Troubleshooting network/remote control errors -40, In case of problems -40 – Cobalt Networks 9084 User Manual

Page 64

Advertising
background image

3

Troubleshooting

3-40

9084 PRODUCT MANUAL

9084-OM (V4.0)

Troubleshooting Network/Remote Control Errors

Refer to Cobalt

®

reference guide “COMPASS™ Remote Control User

Guide” (PN 9000RCS-RM) for network/remote control troubleshooting
information.

In Case of Problems

Should any problem arise with this product that was not solved by the
information in this section, please contact the Cobalt Digital Inc. Technical
Support Department.

If required, a Return Material Authorization number (RMA) will be issued to
you, as well as specific shipping instructions. If required, a temporary
replacement item will be made available at a nominal charge. Any shipping
costs incurred are the customer’s responsibility. All products shipped to you
from Cobalt Digital Inc. will be shipped collect.

The Cobalt Digital Inc. Technical Support Department will continue to
provide advice on any product manufactured by Cobalt Digital Inc., beyond
the warranty period without charge, for the life of the product.

See Contact Cobalt Digital Inc. (p. 1-15) in Chapter 1, “Introduction“for
contact information.

DashBoard™ shows
Framesync Status error
message in 9084 Framesync
function submenu screen.

Specified Minimum Latency
Frames setting exceeds 9084
card buffer space for the
selected output video format

• Reduce the Minimum Latency Frames setting

as specified in the error message to correct
the error.

Note: Due to card memory limits, the maximum

available Minimum Latency Frames is
related to the output video format.
For example, with a 1080i59.94 output, the
maximum allowed setting is 5. For a 1080i
film (23.98) output, the maximum allowed
setting is 3. Conversely, greater maximum
settings are allowed for SD formats such as
525i59.94, where the practical maximum
limit is 13.

Ancillary data (closed captioning,
timecode, AFD, etc.) not
transferred through 9084.

• Control(s) not enabled

• Make certain respective control is set to On or

Enabled (as appropriate).

• VANC line number conflict

between two or more
ancillary data items

• Make certain each ancillary data item to be

passed is assigned a unique line number (see
Ancillary Data Line Number Locations and
Ranges
on page 3-13).

Table 3-5

Troubleshooting Processing Errors by Symptom — continued

Symptom

Error/Condition

Corrective Action

Advertising