Ethernet, Description, Connector & leds – Connect Tech CTIM-00060 User Manual

Page 13

Advertising
background image

Connect Tech Inc. | FreeForm/Express S6 - PCIe Spartan-6 FMC Carrier | User Manual

Revision 0.01

13

Function

Hot Swap
When the is being configured, FPGA I/Os will be pulled
high with weak internal pull-ups

Location

J2

Type

1x2 0.100” jumper block

Pinout

Position

Description

1-2

I/Os have pullups

off

I/Os are floating

Default

Floating

Function

FMC JTAG Bypass
Selects either whether or not to include the FMC module
in the JTA chain

Location

J3

Type

2x2 0.100” jumper block

Pinout

Position

Description

1-3

TDI to FMC

2-4

TDO from FMC

3-4

Bypass

off

Not applicable

Default

Bypass

Ethernet

Description

Two 10/100/1000 Ethernet ports are connected to the FPGA, via two separate RGMII capable Ethernet
physical layer devices (PHYs). The FPGA logic resources are used to implement the Ethernet media
access controller (MAC).

Connector & LEDs

Function Ethernet

Location P6A, P6B

Type

2x5 2mm header
MLE TSHSM-205-D-06-G-V-L (or equivalent)