Char-Broil 4984619 User Manual

Page 6

Advertising
background image

3

- Remove two screws that secure each Electrode to Tube Burner (Electrode remains in Firebox).

- Lift back end of burner while sliding Tube Burner out of Firebox, disengaging burners from Valves.

Electrode

Tube

Burner

Front

of Grill

Firebox

Tube

Burner

Screws

Valve

4

- Insert Orifice Removal Tool provided with Kit into Firebox Burner openings and unscrew Orifices from ends of Valves. Save removed Orifices

for converting back to LP Tank Gas. These grill valves are designed to work with Natural Gas once Orifices are removed. Do not replace any
Orifices when using Natural Gas. Note: This gas conversion kit comes with replacement Orifices for the Rotisserie Burner ONLY, if
applicable, do not use on Tube Burner valves. See later steps for Rotisserie conversion.

Orifice

Orifice Removal Tool

Front

of

Grill

Firebox

Burner

Opening

Valve

Tube

Burner

6 • Natural Gas Conversion Kit

Advertising