I

DD

[19]

V

DD

Operating Supply

V

DD

= Max,

I

OUT

= 0 mA,

f = f

MAX

= 1/t

CYC

200 MHz

(x8)

575

mA

(x9)

575

(x18)

600

(x36)

630

167 MHz

(x8)

485

mA

(x9)

490

(x18)

500

(x36)

540

I

SB1

Automatic Power Down
Current

Max V

DD

,

Both Ports Deselected,
V

IN

≥ V

IH

or V

IN

≤ V

IL

f = f

MAX

= 1/t

CYC

,

Inputs Static

300 MHz

(x8)

275

mA

(x9)

275

(x18)

285

(x36)

300

278 MHz

(x8)

265

mA

(x9)

265

(x18)

275

(x36)

290

250 MHz

(x8)

255

mA

(x9)

255

(x18)

260

(x36)

275

200 MHz

(x8)

245

mA

(x9)

245

(x18)

250

(x36)

260

167 MHz

(x8)

240

mA

(x9)

240

(x18)

245

(x36)

255

AC Electrical Characteristics

Over the Operating Range

[11]

Parameter

Description

Test Conditions

Min

Typ

Max

Unit

V

IH

Input HIGH Voltage

V

REF

+ 0.2

V

V

IL

Input LOW Voltage

V

REF

– 0.2

V

Electrical Characteristics

(continued)

DC Electrical Characteristics

Over the Operating Range

[12]

Parameter

Description

Test Conditions

Min

Typ

Max

Unit

[+] Feedback