Switching characteristics – Cypress CY7C1394BV18 User Manual

Page 24

Advertising
background image

CY7C1392BV18, CY7C1992BV18
CY7C1393BV18, CY7C1394BV18

Document #: 38-05623 Rev. *D

Page 24 of 31

Output Times

t

CO

t

CHQV

C/C Clock Rise (or K/K in single
clock mode) to Data Valid

0.45

0.45

0.45

0.45

0.50

ns

t

DOH

t

CHQX

Data Output Hold after Output C/C
Clock Rise (Active to Active)

–0.45

–0.45

–0.45

–0.45

–0.50

ns

t

CCQO

t

CHCQV

C/C Clock Rise to Echo Clock Valid

0.45

0.45

0.45

0.45

0.50

ns

t

CQOH

t

CHCQX

Echo Clock Hold after C/C Clock
Rise

–0.45

–0.45

–0.45

–0.45

–0.50

ns

t

CQD

t

CQHQV

Echo Clock High to Data Valid

0.27

0.27

0.30

0.35

0.40

ns

t

CQDOH

t

CQHQX

Echo Clock High to Data Invalid

–0.27

–0.27

–0.30

–0.35

–0.40

ns

t

CHZ

t

CHQZ

Clock (C/C) Rise to High-Z
(Active to High-Z)

[24, 25]

0.45

0.45

0.45

0.45

0.50

ns

t

CLZ

t

CHQX1

Clock (C/C) Rise to Low-Z

[24, 25]

–0.45

–0.45

–0.45

–0.45

–0.50

ns

DLL Timing

t

KC Var

t

KC Var

Clock Phase Jitter

0.20

0.20

0.20

0.20

0.20

ns

t

KC lock

t

KC lock

DLL Lock Time (K, C)

1024

1024

1024

1024

1024

Cycles

t

KC Reset

t

KC Reset

K Static to DLL Reset

30

30

30

30

30

ns

Switching Characteristics

(continued)

Over the Operating Range

[20, 21]

Cypress

Parameter

Consortium

Parameter

Description

300 MHz

278 MHz

250 MHz

200 MHz

167 MHz

Unit

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Notes

24. t

CHZ

, t

CLZ

, are specified with a load capacitance of 5 pF as in (b) of

AC Test Loads and Waveforms

. Transition is measured ± 100 mV from steady-state voltage.

25. At any voltage and temperature t

CHZ

is less than t

CLZ

and t

CHZ

less than t

CO

.