Dell PowerEdge 1850 User Manual

Page 17

Advertising
background image

not responding to system
requests.

Error: Incorrect memory configuration.

Ensure memory in slots DIMM1_A and

DIMM1_B, DIMM2_A and DIMM2_B, DIMM3_A

and DIMM3_B match identically in size,

speed, and rank.

One or more unmatched pairs
of memory modules are
detected

Ensure that the memory modules are installed in matched pairs. See "

General

Memory Module Installation Guidelines

" in "Installing System Components."

Error: Incorrect memory configuration.

Memory slots DIMM3_A and DIMM3_B only

support single rank DIMMs. Remove the

dual rank DIMMs from slots DIMM3_A and

DIMM3_B.

Dual rank memory modules
are installed in slots DIMM3_A
and DIMM3_B.

Ensure that only single rank memory modules are installed in slots DIM3_A and
DIMM3_B. See "

General Memory Module Installation Guidelines

" in "Installing

System Components."

Error: Incorrect memory configuration.

Move DIMM3_A and DIMM3_B into DIMM2_A

and DIMM2_B.

Memory modules are not
installed in consecutive banks.

Move memory modules from slots DIMM3_A and DIMM3_B into DIMM2_A and
DIMM2_B. See "

General Memory Module Installation Guidelines

" in "Installing

System Components."

Error: Incorrect memory configuration.

Swap the DIMMs in slots DIMM1_A and

DIMM1_B with DIMMs in slots DIMM2_A

and DIMM2_B.

If dual-rank memory modules
are installed in the system,
they must be installed in slots
DIMM1_A and DIMM1_B.

Swap memory modules in slots DIMM2_A and DIMM2_B with modules in
DIMM1_A and DIMM1_B. See "

General Memory Module Installation Guidelines

" in

"Installing System Components."

Error: Incorrect memory configuration.

Memory slots DIMM3_A and DIMM3_B must

be empty if dual rank memory DIMMS are

in slots DIMM2_A and DIMM2_B.

Memory modules are installed
in bank3. Dual rank memory
modules are installed in banks
1 and 2.

Remove memory modules from slots DIMM3_A and DIMM3_B. See "

General

Memory Module Installation Guidelines

" in "Installing System Components."

 

Error: More than one RAC detected,

system halted.

Two RACs are installed, or
faulty or improperly installed
RAC.

Ensure that only one RAC is installed. Ensure that the RAC is properly installed.
See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System," or

"

Installing a RAC Card

" in "Installing System Options."

Error: Remote Access Card

initialization failure.

Faulty or improperly installed
RAC.

Ensure that the RAC is properly installed. See "

Troubleshooting Expansion

Cards

" in "Troubleshooting Your System," or "

Installing a RAC Card

" in

"Installing System Options."

Error 8602: Auxiliary device failure.

Verify that the keyboard and mouse are

securely attached to correct

connectors.

Loose or improperly
connected mouse or keyboard
cable; faulty mouse or
keyboard.

Replace the mouse. If the problem persists, replace the keyboard.

Gate A20 failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

."

General failure

Operating system corrupted
or improperly installed.

Reinstall the operating system.

Keyboard controller failure

Faulty keyboard controller
(faulty system board).

See "

Getting Help

"

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly
connected keyboard cable;
faulty keyboard; faulty
keyboard controller.

Ensure that the keyboard is properly connected. If the problem persists, replace
the keyboard. If the problem persists, see "

Getting Help

."

 

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

Faulty system board. See "

Getting Help

."

Manufacturing mode detected

System is incorrectly
configured.

After the message appears during system boot, press <Alt><F> to turn off
manufacturing mode.

Memory address line failure at

address, read value expecting value

Memory double word logic failure at

address, read value expecting value

Memory odd/even logic failure at start

address to end address

Memory write/read failure at address,

read value expecting value

Faulty or improperly installed
memory modules, or faulty
system board.

Ensure that all memory modules are properly installed. See "

Troubleshooting

System Memory

" in "Troubleshooting Your System." If the problem persists, see

"

Getting Help

."

Memory mirroring enabled

Memory mirroring enabled

You can enable memory mirroring using the System Setup program if the
memory is configured to support mirroring. For more information, see "

General

Memory Module Installation Guidelines

" in "Installing System Components," and

Using the System Setup Program" in your User's Guide.

Memory tests terminated by keystroke

The spacebar was pressed
during POST to terminate the
memory test.

Information only.

No boot device available

Faulty or missing diskette
drive, optical drive, or hard
drive.

 

Check the Integrated Devices configuration settings in the System Setup
program. See "Using the System Setup Program" in your User's Guide. Ensure
that either SCSI Controller, Diskette Controller, or IDE CD-ROM Controller is
enabled. If the system is booting from a SCSI controller, ensure that the
controller is properly connected. If the problem persists, replace the drive. See
"

Installing Drives

."

No boot sector on hard-disk drive

An operating system is not on
the hard drive.

Check the hard drive configuration settings in the System Setup program. See
"Using the System Setup Program" in your User's Guide.

No timer tick interrupt

Faulty system board.

See "

Getting Help

."

Not a boot diskette

Not a bootable diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion
card(s); faulty or improperly
installed expansion card.

Ensure that all appropriate cables are securely connected to the expansion
cards. See "

Troubleshooting Expansion Cards

," in "Troubleshooting Your

System."