Firmware update – Dell PowerEdge C5230 User Manual

Page 13

Advertising
background image

11

Firmware Update

Use the Firmware Update feature to upgrade to the latest firmware version.

The following data is included in the BMC firmware package:

• Compiled BMC firmware code and data
• Web-based user interface, JPEG, and other user interface data files
• Default configuration files

Updating the BMC Firmware

NOTE:

Before beginning the firmware update, download the latest firmware

version and save it on your local system. During the process of firmware update, the

AC power of the managed system cannot be unplugged and the Web GUI cannot be

closed.

NOTE:

Once you enter into Update Mode and choose to cancel the firmware flash

operation, the BMC must be reset. This means that you must close the Internet

browser and log back onto the BMC card before you can perform any other types of

operations.

Select the Enter Update Mode button from the Maintenance tab to put the

device in a special mode that allows firmware update. You can now follow the

instructions presented below to successfully update the card’s firmware. The

device resets if update is cancelled. The device also resets upon successful

completion of firmware update.

1 Browse to, or enter the path on your system where the firmware image file

resides.
Example:
C:\Updates\V1.0\<image_name>
The default firmware image name is s81s

XXX

.bin (whereas XXX is the

version number).

2 Select Auto Reset BMC if you want the BMC to auto reset after the

update.

3 BMC will not check if the Firmware image belongs to C5230 platform

when selecting

Force Update.

4 Click the Upload Firmware button.
5 BMC will save configure settings when Preserve Configuration is selected.