See "blinking fault, Led conditions" on – Dell PowerEdge C5230 User Manual

Page 16

Advertising
background image

14

Table 1-6. Blinking Fault LED Conditions

ID LED

Blue

Off

Normal status (by IPMI
Chassis Identify
command or System ID
Button)

Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00

Solid On Identify the system

Turn on the ID LED.
1.ipmitool raw 0x00 0x04 0x3c
01

Blinking Identify the system with

interval

1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60 sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)

Heartbeat

LED

Green On

BMC is not ready

Blinking BMC is ready

Index

Sensor Name

Event Triggers

1

Memory Error

0: Correctable error
1: Uncorrectable error
5: Correctable ECC error logging limit reached

2

POST Error

Defined by BIOS and this sensor logged by BIOS.

3

PCIE Error

7: Bus correctable error
8: Bus Uncorrectable error
A: Bus fatal

Table 1-5. LED Status