Performance issues, Fc-fc routing connectivity – Dell POWEREDGE M1000E User Manual

Page 37

Advertising
background image

Fabric OS Troubleshooting and Diagnostics Guide

21

53-1002751-01

FC-FC routing connectivity

2

switch:admin> pathinfo 5

Hop In Port Domain ID (Name) Out Port BW Cost

-----------------------------------------------------------------------------

0 2

1 (sw0)

6 4G 500

1 23

2 (sw0) 8 4G 500

2 4

3 (sw0) 3 4G 500

3 12

4 (sw0)

18 4G 10000

4 4

7 (switch_3)

0 4G 500

5 26

5 (switch_3) E - -

To display basic and extended statistics in interactive mode:

switch:admin> pathinfo

Max hops: (1..127) [25]

Fabric Id: (1..128) [-1]

Domain|Wwn|Name: [] 8

Source port: (0..15) [-1]

Destination port: (0..255) [-1]

Source pid: (0x0..0xefff00) [ffffffff] 0x061600

Desination pid: (0x0..0xefff00) [0] 0x01f001

Basic stats (yes, y, no, n): [no] y

Extended stats (yes, y, no, n): [no] y

Trace reverse path (yes, y, no, n): [no]

Source route (yes, y, no, n): [no]

Timeout: (1000..30000) [10000]

Target port is Embedded

Hop In Port Domain ID (Name) Out Port BW Cost

-----------------------------------------------------------------------------

0 2 1 (sw0) 6 4G 500

1 23 2 (sw0) 8 4G 500

2 4 3 (sw0) 3 4G 500

3 2 4 (sw0) 24 4G 10000

4 3 7 (switch_3) 2 4G 500

5 27 5 (switch_3) 24 - -

Reverse path

6 24 5 (switch_3) 27 4G 500

7 2 7 (switch_3) 3 4G 500

8 24 4 (sw0) 2 4G 500

9 3 3 (sw0) 4 4G 10000

10 8 2 (sw0) 23 4G 500

11

6

1 (sw0)

2

-

-

(output truncated)

For details about the pathInfo command, refer to the Fabric OS Command Reference.

Performance issues

Symptom

General slow-down in FCR performance and scalability.

Probable cause and recommended action

As LSAN zone databases get bigger, it takes more switch resources to process them. Use the
enforce tag feature to prevent a backbone switch from accepting unwanted LSAN zone databases
into its local database.

Advertising