Switch configuration blade compatibility

7

Symptom

A non-GE blade is within the slot range.

Probable cause and recommended action

You are attempting to configure a GE port on a slot that does not contain GE ports.

Symptom

A port or ports is already in the current switch.

Probable cause and recommended action

You may not move a port to the same switch.

Symptom

The maximum number of switches for this platform has been reached.

Probable cause and recommended action

Each platform that supports Virtual Fabrics has a maximum number of logical switches that may be
supported. The platform has reached this limit.

Symptom

Unable to create the switch.

Probable cause and recommended action

There was an error while creating the switch.

Symptom

A port or ports cannot be moved to the requested switch because it would exceed the 256 area
limit for this switch.

Probable cause and recommended action

The area limit would be exceeded if the lsCfg command were allowed.

Symptom

A port or ports cannot be moved to the requested switch because it may only exist in a base or
default switch.

Probable cause and recommended action

You are attempting to move ports on a core blade into a nondefault or non-base switch.

Switch configuration blade compatibility

Symptom

A slot in the chassis displays a FAULTY(91) in the output of the slotShow command.

Probable cause and recommended action

When an enterprise-class platform is coming up or when a blade is inserted, the switch
configuration is checked based on the blade type. If the configuration does not match with the
blade type, the blade is faulted. This is displayed as FAULTY(91) in the output of the slotShow
command.

Use the lsCfg –restore_slot_to_default command to correct the problem. Once the configuration
discrepancy has been fixed, you may use slotPowerOff followed by slotPowerOn to recover.

>lscfg –restore_slot_to_default 1

>slotpoweroff 1

>slotpoweron 1

Slot Blade Type ID Model Name Status

--------------------------------------------------

1 SW BLADE 77 FC8-64 ENABLED