Dell Precision T1600 (Early 2011) User Manual

Page 77

Advertising
background image

Error Message

Description

memory modules and, if necessary,

replace them.

Diskette drive 0 seek failure

A cable may be loose or the computer

configuration information may not match

the hardware configuration.

Diskette read failure

The floppy disk may be defective or a

cable may be loose. If the drive access

light turns on, try a different disk.

Diskette subsystem reset failed

The floppy drive controller may be faulty.

Drive not ready

No floppy disk is in the drive. Put a floppy

disk in the drive.

Diskette write protected

The floppy disk is write-protected. Slide

the write-protect notch to the open

position.

Gate A20 failure

One or more memory modules may be

faulty or improperly seated. Reinstall the

memory modules and, if necessary,

replace them.

General failure

The operating system is unable to carry

out the command. This message is usually

followed by specific information—for

example, Printer out of paper. Take the

appropriate action to resolve the problem.

Hard-disk drive configuration error

The hard drive failed initialization.

Hard-disk drive controller failure

The hard drive failed initialization.

Hard-disk drive failure

The hard drive failed initialization.

Hard-disk drive read failure

The hard drive failed initialization.

Invalid configuration information-please

run SETUP program

The computer configuration information

does not match the hardware

configuration.

Invalid Memory configuration, please

populate DIMM1

DIMM1 slot does not recognize a memory

module. The module should be re-seated

or installed.

Keyboard failure

A cable or connector may be loose, or the

keyboard or keyboard/mouse controller

may be faulty.

77

Advertising