Debugging spinfab errors, Link errors – Dell POWEREDGE M1000E User Manual

Page 105

Advertising
background image

Fabric OS Troubleshooting and Diagnostics Guide

91

53-1001769-01

SpinFab and portTest

10

CAUTION

During the spinFab testing, the switch remains in normal operation. However, some performance
degradation will occur due to the ISL links being saturated with the test frames. This test should
be run with caution on a live fabric.

Table 15

lists the supported ports for the specified version of Fabric OS when using the spinFab

command.

Debugging spinFab errors

Link errors and tx/rx errors are seen when the spinFab test fails.

Link Errors

Once the frame is sent out of the port, the spinFab command monitors the link errors in the ASIC.
If any of the error counters are non-zero, spinFab reports ERROR and the test fails on the port.

ERROR: DIAG ERRSTAT spinfab, pass 6,

Pt0/17(7) Ch0/7 CRC_err Error Counter is 109738997 sb 0,

ERROR: DIAG ERRSTAT spinfab, pass 1,

Pt0/3(33) Ch0/33 Enc_in Error Counter is 32 sb 0,

ERROR: DIAG ERRSTAT spinfab, pass 1,

TABLE 15

Port type support

Port type

Supported in v6.2.0

Supported in v6.3.0

Supported in v6.4.0

Loopback

Yes

Yes

Yes

E_Ports

Yes

Yes

Yes

Trunk Master ports

Yes

Yes

Yes

Ports beyond index 255

No

Yes

Yes

Ports with swapped areas

No

Yes

Yes

Shared-area ports

No

Yes

Yes

Ports in logical switches

No

Yes

Yes

Ports in base switches

No

Yes

Yes

Trunk slave ports

No

No

Yes

Long distance ports

No

No

Yes

F_Ports connected to Brocade HBAs

No

No

Yes

1

1.

If you use the spinFab command to test F_Ports connected to Brocade HBAs it is required that the

firmware version on the HBA is v2.1.1 or later.

ICL ports

No

No

No

F_Ports connected to Access Gateway

No

No

No

EX_Ports

No

No

No

Ports in an Access Gateway switch

No

No

No

Advertising