Fabric OS MIB Reference

53-1001768-01

fcFxPortHoldTime 1.3.6.1.2.1.75.1.1.5.1.14

3

fcFxPortHoldTime 1.3.6.1.2.1.75.1.1.5.1.14

The maximum time (in microseconds) that the Fx_Port holds a frame before discarding the frame if
it is unable to deliver the frame. The value 0 means that the Fx_Port does not support this
parameter. The formula used to calculate this object is (RATOV - EDTOV - (2 * WAN_TOV)) /
(MAX_HOPS + 1)) / 2).

fcFeStatus group

This group consists of tables that contain operational status and established service parameters
for the fabric element and the attached Nx_Ports.

fcFxPortStatusTable 1.3.6.1.2.1.75.1.2.1

A table that contains operational status and parameters of the Fx_Ports, one entry for each Fx_Port
in the fabric element.

fcFxPortStatusEntry 1.3.6.1.2.1.75.1.2.1.1

An entry containing operational status and parameters of an Fx_Port.

Augments

1: fcFxPortEntry

fcFxPortID 1.3.6.1.2.1.75.1.2.1.1.1

The address identifier by which this Fx_Port is identified within the fabric. The Fx_Port might assign
its address identifier to its attached Nx_Ports during fabric login.

fcFxPortBbCreditAvailable 1.3.6.1.2.1.75.1.2.1.1.2

The number of buffers currently available for receiving frames from the attached port in the
buffer-to-buffer flow control. The value should be less than or equal to fcFxPortBbCredit.

fcFxPortOperMode 1.3.6.1.2.1.75.1.2.1.1.3

The current operational mode of the Fx_Port.

Values

Possible values are:

1: unknown (1)

2: fPort (2)

3: flPort (3)