Cmc8529, Cmc8531 – Dell PowerEdge VRTX User Manual

Page 119

Advertising
background image

Detailed
Description

CMC is unable to obtain the link tuning information for the newly installed hardware (server,
Input Output Module, or Mezzanine card), or is unable to send the link tuning information to
iDRAC.

Recommended
Response Action

Make sure that the currently installed CMC firmware is the latest. Otherwise, update the CMC
with the latest CMC firmware and retry the operation.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 2 (Warning)

Trap/EventID

2546

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8529

Message

Unable to perform the requested action on the server-

arg1

, because of insufficient privileges.

Arguments

arg1 =

slot number

Detailed
Description

The user account does not have sufficient privileges to perform the requested operation.
Server Administrator privilege is required to perform the requested action.

Recommended
Response Action

Use a different user account that has Server Administrator privilege, and retry the operation.
For more information, contact your system administrator or service provider.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8531

Message

Unable to perform the requested action on the sleeve

arg1

because of insufficient user

privileges.