Stor event messages, Stor1, Stor2 – Dell PowerEdge VRTX User Manual

Page 713: 39 stor event messages

Advertising
background image

39

STOR Event Messages

STOR1

Message

A device

arg1

is in an unknown state.

Arguments

arg1 =

device name

Detailed
Description

The controller cannot communicate with a device. The state of the device cannot be
determined. There may be a bad or loose cable, or a missing device, or a problem with the
driver or firmware.

Recommended
Response Action

See the storage hardware documentation for information on checking the cables. Check for
problems with any enclosures attached to the system. Verify that the controller has a
supported version of the driver and firmware. Rebooting the system may resolve this problem.

Category

Storage

SubCategory

STOR = Storage

Severity

Severity 2 (Warning)

Trap/EventID

4178

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

STOR2

Message

SCSI sense data

arg1

.

Arguments

arg1 =

args

Detailed
Description

A SCSI device experienced an error, but may have recovered.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

STOR = Storage

713