Warning! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Warning!

Performance

degraded. CPU and

memory set to

minimum

frequencies to

meet PSU wattage.

System will

reboot.

The system configuration of

processor(s), memory

modules, and expansion

cards may not be supported

by the power supplies.

If any system components

were just upgraded,

return the system to the

previous configuration. If

the system boots without

this warning, then the

replaced component(s) are

not supported with this

power supply. If Energy

Smart power supplies are

installed, replace them with

the High Output power

supplies to use the

components. See "Power

Supplies" on page 79.

Warning! PSU

mismatch. PSU

redundancy lost.

Check PSU.

A High Output power supply

and an Energy Smart power

supply are installed in the

system at the same time.

Install two High Output

or two Energy Smart power

supplies in the system.
You can also run the system

on one power supply until

you can obtain two power

supplies of the same type.

See "Troubleshooting Power

Supplies" on page 135.

Warning!

Unsupported

memory

configuration

detected. The

memory

configuration is

not optimal. The

recommended

memory

configuration

is: <message>

Invalid memory

configuration. The system

runs but with reduced

functionality.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module

Installation Guidelines" on

page 83. If the

problem persists,

see "Troubleshooting System

Memory" on page 137.

Message

Causes

Corrective Actions