Dell PowerEdge VRTX User Manual

Page 146

Advertising
background image

(Slot 3) One standard height, full-length x8 link

System board

(Slot 4) One low profile, half-length x8 link

(Slot 5) One low profile, half-length x8 link

(Slot 6) One low profile, half-length x8 link

(Slot 7) One low profile, half-length x8 link

(Slot 8) One low profile, half-length x8 link

Power

AC power supply (per power supply)

Wattage

1100 W
1600 W (800 W low line intended usage 100 – 127 V AC)

Connector

IEC C14

Heat dissipation

4100 BTU/hr (maximum for 1100 W power supply)
3000 BTU/Hr (maximum for the 1600 W power supply de-

rated to 800 W for low line operation)
6000 BTU/Hr (maximum for the 1600 W power supply for

high line operation)

System voltage requirements

100 – 240 V AC, 50/60 Hz (1100 W power supply)
100 – 127 V AC, 50/60 Hz (1600 W power supply de-rated to

800 W)
200 – 240 V AC, 50/60 Hz (1600 W power supply)

Battery

3 V CR2032 Lithium coin cell

Drives

Controller type

Shared PERC 8

Hard drives

12 hard-drive systems

Up to twelve 3.5 inch, hot-swappable SAS, SAS SSD, or

Nearline SAS hard drives.

25 hard-drive systems

Up to twenty-five 2.5 inch, hot-swappable SAS, SAS SSD,

or Nearline SAS hard drives.

Optical drive

One optional SATA DVD-ROM drive or DVD+RW drive.

NOTE: DVD devices are data only.

Chassis Management Controller

Externally accessible connectors

Remote management

Two dedicated 10/100/1000 Mb RJ-45 (for integrated

Ethernet remote access controller).

Serial

9-pin, DTE, 16550-compatible

Enclosure Control Panel

Externally accessible connectors

146

Advertising