Output relays & configuration switch settings, Setting output relay mode, Setting the configuration switch – Chamberlain TCR2 User Manual

Page 3: Figure 2, Setting the configuration switch the tricode, Receiver is factory set for linear/delta-3, Works with all “linear/delta-3, Works with all “multi-code, Works with all “stanley

Advertising
background image

3

OUTPUT RELAYS & CONFIGURATION SWITCH SETTINGS

Figure 2

Delta-3/ Linear

Multi-Code

Stanley

310 MHz

300 MHz

310 MHz

TM

TM

TM

Configuration

Switch

Setting the Configuration Switch

The TriCode

®

receiver is factory set for Linear/Delta-3

TM

.

Locate the configuration switch and set it to the desired RF mode
of operation (Figures 2 and 3). Modes are as follows:

Linear/Delta-3

TM

: works with all “Linear/Delta-3

TM

” transmitters

transmitted at 310 MHz using 8-bits ID system.

Multi

TM

: works with all “Multi-Code

TM

” transmitters transmitted at

300 MHz using 10-bits ID system.

Stanley

TM

: works with all “Stanley

TM

radio” transmitters

transmitted at 310 MHz using 10-bits ID system.

Setting Output Relay Mode

The TriCode

®

receiver is factory set for momentary relay output

“MNT”.

• Momentary mode: The output relay will be on for .5 seconds

before turning off.

• Constant pressure mode: Output relay is continuously on

while receiving matching/valid ID code from transmitter. The
output relay will turn off immediately once receiver does not
receive a matching/valid ID code from the transmitter
(Figure 3).

NOTE: If constant pressure mode is desired, open front cover
and move mode jumper from “MNT” to “CST” (Figure 2).

Figure 3

CH1

MODE

CST MNT

CH2

MODE

CST MNT

Relay

CH1-mode

Relay

CH2-mode

Configuration

Switch

Delta-3/Linear
Multi-Code
Stanley

TM

TM

TM

LINEAR

MULTI

STAN

TM

TM

TM

CH2
MODE

CST MNT

CH1

MODE

CST MNT

Advertising