Dip switch settings & power connections, Setting dip switch, Power supply and relay out connections – Chamberlain TCR2 User Manual

Page 4: For installation and service information, Setting dip switch the tricode, Multi-code, Or stanley, Figure 5

Advertising
background image

© 2007, The Chamberlain Group, Inc.

01-17468D

All Rights Reserved

Setting DIP Switch

The TriCode

®

Receiver DIP switch CH1 is factory set OFF (1-10)

and CH2 is factory set ON (1-10).

Locate the 10 position DIP switch. If this is a new installation
using TriCode

®

transmitters, randomly set switches matching

those of the transmitter. Never use factory settings. If receiver is
used with Linear/Delta 3

TM

, Multi-Code

TM

or Stanley

TM

transmitters,

match the receiver DIP switch to the above transmitters. Some
transmitters may use toggle switches and it may be difficult to
determine on & off. If so, try reversing the setting on the
TriCode

®

DIP switch (Figures 4 and 5).

NOTE: In 'LINEAR/DELTA-3

TM

' mode (8-bits system) the last 2

bits (DIP #9 & 10) settings are ignored. They can be left in either
‘ON’ or ‘OFF’ settings.

Figure 4

DIP SWITCH SETTINGS & POWER CONNECTIONS

Multi/ Stanley

(1 Thru 10)

Linear/ Delta-3

(1 Thru 8)

1 2 3 4 5 6 7 8 9 10

O
N

O
F
F

TM

TM

DIP

Switch

For installation and service information please

call our toll free number:

1-800-528-2806

or contact us through the web at

www.chamberlaingroup.com

Power Supply and Relay out Connections

There are six wires exiting the housing (Figure 6):

RED & BLACK - POWER INPUT

BROWN & BLUE - CHANNEL 1 RELAY OUTPUT

WHITE & GREEN - CHANNEL 2 RELAY OUTPUT

Figure 6

DIP

Switches

Channel 2 DIP Switch

Channel 1 DIP Switch

1

2 3

4 5

6

7 8 9 10

O
N

1

2 3

4 5

6

7 8 9 10

O
N

1

2

3

4

5

6

7

8

9 10

O
N

1

2

3

4

5

6

7

8

9 10

O
N

Figure 5

Relay
Output
Ch1

Relay
Output
Ch2

Red

Black

Brown

Blue

White

Green

Power

Supply

12V/24V

Advertising