Surge suppression, Optical isolation, Dimensions – Connect Tech Blue Heat/PCI PCI Serial Communications User Manual

Page 19

Advertising
background image

Blue Heat/PCI User’s Manual, Connect Tech Inc.


19

Revision

0.11

Control Signals (continued)

„

Blue Heat/PCI CL Models:

• 20mA

TxD; RxD

Surge Suppression

„

Blue Heat Models:

• 500 watts, 8 x 20 µS (EN61000-4-2/3/4 compatible) on every signal of every port.

„

Blue Heat/PCI RS-422/485; Universal Blue Heat/PCI RS-422/485 Models:

• TransGuard

Transient Voltage Suppression, able to withstand multiple strikes on every

signal of every port.
• Transient Energy dissipation 0.1 joules on every signal of every port
• Transient peak current dissipation 40A on every signal of every port
• EN61000-4-2/3/4 compatible

Optical Isolation

„

Blue Heat/PCI Opto; Opto RS-422/485 Models:

• 1K or 2.5kV AC peak to peak on every signal of every port.

Dimensions

„

Blue Heat/PCI (2, 4 & 8 port models)

Length:

12.25 cm

Width:

1.50 cm

Height:

10.50 cm

Weight: 0.12 kg

„

Blue Heat/PCI RS-422/485 (8 port & 4+4 models)

Length:

17.30 cm

Width:

1.50 cm

Height:

10.50 cm

Weight: 0.20 kg

„

Blue Heat/PCI RS-422/485 (6+2 model)

Length:

13.62 cm

Width:

1.50 cm

Height:

10.50 cm

Weight: 0.12 kg

„

Blue Heat/PCI RS-422/485 (4 port & 2+2 models)

Length:

12.00 cm

Width:

1.50 cm

Height:

10.50 cm

Weight: 0.15 kg

„

Blue Heat/PCI RS-422/485 (2 port model)

Length:

12.00 cm

Width:

1.50 cm

Height:

9.50 cm

Weight: 0.13 kg

„

Blue Heat/PCI RJ-11

Length:

12.25 cm

Width:

1.12 cm

Height:

10.60 cm

Weight: 0.12 kg

Advertising