3. PolarCool Performance

The following table shows estimates of the performance of three sizes of the PolarCool Evaporative Cooling
System. These values will vary depending on the particular installation and operating conditions. Both Variable
Speed(VS) and Single Speed(SS) models are listed.

PolarCoo

l Model

Drive

Water Consumption

Rates

(See Note 1)

Power Consumption

Typical Air

Movement Rates

(cubic feet per

minute- See Note 2)

18” VS

Direct

5 gallons per hr.

5 amps @ 115v /60hz

3,000

18” VS

Direct

5 gallons per hr.

3.5 amps @ 230v /50hz

3,000

24” VS

Direct

7 gallons per hr.

6 amps @ 115v /60hz

4,400

24” VS

Direct

7 gallons per hr.

3.5 amps @ 230v /50hz

4,400

36” VS

Direct

12 gallons per hr.

10 amps @ 115v /60hz

10,000

36” VS

Direct

12 gallons per hr.

5.5 amps @ 230v /50hz

10,000

36” SS

Direct

10 gallons per hr.

7.0 amps @ 115v /60hz

10,000

48” SS

Belt

17 gallons per hr.

11 amps @ 230v /60hz

17,500

48” SS

Belt

17 gallons per hr.

8 amps @ 230v /50hz

17,500


Note 1: This estimate is under 90+ degree conditions; cooler temperatures will result in less

water usage.


Note 2: The cooling area is very dependent on the relative humidity, temperature, and the space

being cooled.

3.1

Temperature Differential Readings

The temperature drop from inlet to exit is very dependent on relative humidity and temperature. The higher the
ambient temperature and the drier the air, the greater the drop. A temperature drop of 10 to 20 degrees is common.