11. When the test is completed, the display shows the actual volts and the actual CCA

and/or {Press the s

\

t

key to select: SOH (STATE OF HEALTH) or SOC (STATE OF

CHARGE)}. One of six results will be displayed:

GOOD & PASS :
The battery is good & capable of holding a charge.

GOOD & RECHARGE :
The battery is good but needs to be recharged.

RECHARGE & RETEST :
Battery is discharged, the battery condition cannot
be determined until it is fully charged. Recharge &
retest the battery.

BAD & REPLACE :
The battery will not hold a charge. It should be
replaced immediately.

BAD CELL & REPLACE :
The battery has at least one cell short circuit.
It should be replaced immediately.

LOAD ERROR :

The tested battery is bigger than 2000CCA or 200AH.
Or the clamps are not connected properly. Please fully
charge the battery and retest after eliminating both
previous potential causes for load error message. If
reading is the same, the battery should be replaced immediately.

*Ask the operator if any accessories have been left on as a possible cause of battery problem. If
response is Yes – charge and retest the battery. If accessories have not been left on, replace the bat-
tery, since the charging system is working and a good battery should have accepted a charge.

At the end of step 11 your Battery only test is complete.

12. If a System Test is also to be performed - Press «ENTER» and Press the s

\

t

key to

select: System Test or remove the test clamps from the battery posts after completion
of testing batteries to end test and/or start over.

GOOD & PASS