FibreQuik - Fibre Channel Adapter User Guide

lscfg -vl scsi4

should print more information for a card:

DEVICE LOCATION DESCRIPTION
scsi4 20-58 Cambex ...

Manufacturer................CAMBEX
Machine Type and Model......PC1000F
ROS Level and ID............V2.01.19
Serial Number............... 579
Displayable Message.........Cambex ...
Network Address.............500502E010000243
Device Specific.(Z0)........Build:TMFtL
Device Specific.(Z1)........1.5.13.0
Device Specific.(YL)........P1-I1/Z1

lsattr -El scsi4

should print the attributes for a card.

These are also displayed by SMIT in Change / Show
Characteristics of an Adapter.

bus_io_addr

Bus address of board I/O registers

bus_intr_lvl

Bus interrupt level

intr_priority Interrupt

priority

id

Adapter card loop ID

exec_throttle Max commands per port
max_iocb

Max bufers per port

retry_delay

Delay amount after bus reset (sec)

login_on_lip

Login all devices after LIP

full_duplex

Use open full duplex (OPNyx)

topology_list Prioritized topology list
frame_size

Max payload frame length

infinity

Command timeout infinity (sec)

dma_window

DMA window size for 64 bit PCI

GHz

Fibre channel rate in GHz

sw_fc_class

Class of service

devtype_exclude

SCSI device type exclude list

logout_delay

Delay amount after device logout

BDR_mask Mask bus device resets


• ID may be used to set a hard card loop ID if required.
• Exec_throttle may be used to limit simultaneous I/Os to avoid

"device busy" errors.

• Max_iocb is not used.