Scilogex SK-O180-Pro User Manual

Page 7

Advertising
background image

5

SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker

• Put the instrument on stable and safe place and plug in the

mains power.

• Turn ON the mains switch on the left panel.

• The instrument starts self-test.

• The instrument shows rated speed and time after

initialization.

• Turn the speed knob on the left side to set the rated speed.

• Press the speed knob and characters on the left LCD do

not flash any more, and the shaking function is switched ON.

• Press the speed knob again and characters on the left LCD

begin to flash, and the shaking function is switched OFF.

• Turn the time knob on the left side to set the rated time

• Press the time knob and characters on the LCD do not

flash any more, and the timing function is switched ON.

• Press the time knob again and characters on the right LCD

begin to flash, and the timing function is switched OFF.

5.2 Set

5.2.1 Set time

The rated shaking time can be set by turning the time knob

on the right. A distinction is made for the shaking time

setting between timed mode and continuous operation. If

continuous mode is selected, the shake can continue its

shaking function for any amount of time with the previously

set speed. If timed mode is selected, the shaker can run in the

set time. After the instrument is powered OFF and restarted,

the set time is erased to zero blanking and it switches into

offline operating mode.

If a target time (max. 19h 59min) and speed are set, users

can activate the instrument with pressing the time knob,

and the time begin to read,If:

A,pressing the time knob,the speed and the time

will stop. Pressing the time knob again,restart the shake

function,the time will use the pre-set time

B,pressing the speed knob,the speed and the time

will stop; Pressing the time knob again,restart the shake

function,the time not(There are flashing on the righe of

the LCD ),pressing the time knob again restart the time

function. The time will use the pre-set time.

Note:

The current set time can be varied at any time.

5.2.2 Setting Speed

The rated speed and upper speed limit can be set by turning

the speed knob (As the Figure 6) . The continuous mode can

be switched ON with pressing the left knob without the time

setting and switched OFF with pressing the knob again..

Adjust the motor speed knob slowly in order to keep the

instrument running smoothly.