Electrical feeder cable

connection

To connect the feeder cable to the
cooker it is necessary to:

– Remove the 2 screws that hold shield

A behind the cooker.

– Open completely the cable clamp D.

– Insert the feeder cable into the cable

save P. The supply cable must be of a
suitable size for the current require-
ments of the appliance; see the
section “Feeder cable section”.

– Connect the phase and earth cables

to terminal B according to figures 45
and 46.

– Pull the feeder cable and block it with

the cable clamp D.

– Re-mount shield A.

N.B. The earth conductor must be
left about 3 cm longer than the
others.

Fig. 45

Feeder cable section

type H05RRF

230 V

3 x 2,5 mm

2

(**)

(**) –

Connection with wall box connection.

P

D

B

A

230 V

PE

N

L

1

(L

2

)

Fig. 46

PE Earth

N

Neutral

L

Live