Additional Information

Warning Messages

If there is something wrong with the input signal, one of the

following messages appears.

©INFORMATION

pfl—4|oUT

OF

SCAN

range

!

[

2

]------^INPLfT : HDlT|

m The input signal condition

"OUT OF SCAN RANGE" indicates that the input signal
is not supported by the moiutor's specifications.

"NO INPUT SIGNAL" indicates that no signal is input, or
the input signal from the selected input connector is not
received.

[

2

I The selected input connector

Indicates which input connector is receiving the wrong
signal. If there is something wrong with the signal from
both input connectors, "HD15" and "BNC" are
displayed alternately.

To solve these problems, see "Troubleshooting" below.

'I!

Troubleshooting

This section may help you isolate the cause of a problem and as a result, eliminate the need to contact technical support.

Symptom

Check these items

No picture

If the C!) indicator is not lit

• Check that the power cord is properly connected.
• Check that the Cl) (power) switch is in the "on" position.

If the "NO INHJT SIGNAL"

message appears on the screen,

or if the C!) indicator is cither
orange or alternating between

green and orange

• The screen is blank when the monitor is in power saving mode. Try pressing any key on the

computer keyboard.

• Check that your computer power switch is in the "on" position.
• Check that the input select setting is correct.
• Check that the video signal cable is properly connected and all plugs are firmly seated in

their sockets.

• Check that the 5 BN<Z!s are connected in the correct order (from left to right; Red-Green-

Blue-HD-VD) (page 6).

• Ensure that no pins are bent or pushed in the HD15 video input connector.
• Check that the video board is completely seated in the proper bus slot.

If the "OUT OF SCAN RANGE"
message appears on the screen

• Check that the video frequency range is within that specified for the monitor.

Horizontal; 30 - 94 kHz (GDM-400PS), 30 -107 kl Iz (GDM-500PS)
Vertical; 48 -160 Hz
Refer to your computer's instruction manual to adjust the video frequency range.

• If you are using a video signal cable adapter, check that it is correct.

If no message is displayed and
the (!) indicator is green or
flashing orange

• See "Self-diagnosis Function" (page 22).

If using a Macintosh system

• Check that the Macintosh adapter and the video signal cable are properly connected (page

6).

If using Windows* 95

• If you cannot find your model's name (GDM-400PS or GDM-500PS) among the Sony

monitors in the Windows 95 monitor selection screen, select the DDC standard monitor or
install the Windows 95 Monitor Information Disk (page 7).

The DDC standard does not apply to the 5 BNC connectors. If you use the DDC standard,

connect the computer to the HD15 connector with the supplied video signal cable.

Picture is scrambled

Check your graphics board manual for the proper monitor setting.
• Check this manual and confirm that the graphics mode and the frequency you are trying to

operate at is supported. Even if the frequency is within the proper range, some video

boards may have a sync pulse that Is too narrow for the monitor to sync correctly.