Refer to FIGURE 2 for the depth requirements of a hearth extension. Hearth extension
requirements vary according to where the floor joists meet the hearth and what local code requires.

FIGURE 4:

INSIDE WALL PAD INSTALLATION

NOTES:

1.

If installing a fireplace furnace on an inside wall, refer to FIGURE 4. An inside wall
concrete pad must be six inches deeper than FIGURE 3 shows to allow for additional air
space required for inside wall installation.


2.

Overall concrete pad and hearth extension sizes can be determined by referring to
FIGURE 3. Remember that a pad should contain rebar or steel mesh for stress reduction
and improved strength.

Version 7.1

7

3.

All combustible ash pit forms should be removed before the concrete pad is poured, as
removal will be impossible once the concrete pad has been poured.