• Keep battery and terminals clean.
• Keep battery bolts tight.
• Keep small vent holes open.
• Recharge at 6-10 amperes for 1 hour.

NOTE: The original equipment battery on

your tractor is maintenance free. Do not
attempt to open or remove caps or covers.
Adding or checking level of electrolyte is
not necessary.

TO CLEAN BATTERY AND TERMINALS
Corrosion and dirt on the battery and
terminals can cause the battery to “leak”

power.
1. Remove terminal guard.

2. Disconnect BLACK battery cable first

then RED battery cable and remove

battery from tractor.

3. Rinse the battery with plain water and

dry.

4. Clean terminals and battery cable

ends with wire brush until bright.

5. Coat terminals with grease or petro­

leum jelly.

6. Reinstall battery (See “REPLACING

BATTERr* in the SERVICE AND

ADJUSTMENTS section of this

manual).

V-BELTS
Check V-belts for deterioration and wear

after 100 hours of operation and replace
if necessary. The belts are not adjustable.

Replace belts if they begin to slip from

wear.

TRANSAXLE COOLING
The transmission fan and cooling fins

should be kept clean to assure proper
cooling.

Do not attempt to clean fan or transmis­

sion while engine is running or while the
transmission is hot. To prevent possible
damage to seals, do not use high
pressure water or steam to clean

transaxle.

• Inspect cooling fan to be sure fan

blades are intact and clean.

• Inspect cooling fins for dirt, grass

clippings and other materials. To

prevent damage to seals, do not use

compressed air or high pressure
sprayer to clean cooling fins.

TRANSAXLE PUMP FLUID

The transaxle was sealed at the factory
and fluid maintenance is not required for
the life of the transaxle. Should the
transaxle ever leak or require servicing,
contact a Sears or other qualified service
center.

ENGINE

LUBRICATION

Only use high quality detergent oil rated
with API service classification SF-SJ.
Select the oil’s SAE viscosity grade
according to your expected operating
temperature.

SAE VISCOSITY GRADES

30

32

*

40

*

*C

-

30

*

20

*

10

*

10

*

20*

30

*

TEMPERATURE RANGE ANTICIPATCP BEFORE NEXT OIL CHANGE

22

Change the oil after every 50 hours of
operation or at least once a year if the
tractor is not used for 50 hours in one
year.
Check the crankcase oil level before

starting the engine and after each eight
(8) hours of operation. Tighten oil fill cap/
dipstick securely each time you check the
oil level.

TO CHANGE ENGINE OIL

Determine temperature range expected
before oil change. All oil must meet API
service classification SF-SJ.
* Be sure tractor is on level surface.
* Oil will drain more freely when warm.
* Catch oil in a suitable container.

1. Remove oil fill cap/dipstick. Be careful

not to allow dirt to enter the engine

when changing oil.

2. Remove cap from end of drain valve

and install the drain tube onto the

fitting.

3. Unlock drain valve by pushing upward

slightly and turning counterclockwise.

4. To open, pull down on the drain valve.

5. After oil has drained completely, close

and lock the drain valve by pushing
upward and turning clockwise until the
pin is in the locked position as shown.

6. Remove the drain tube and replace

the cap onto to the end of the drain
valve.

7. Refill engine with oil through oil fill

dipstick tube. Pour slowly. Do not
overfill. For approximate capacity see
“PRODUCT SPECIFICATIONS"
section of this manual.

8. Use gauge on oil fill cap/dipstick for

checking level. Insert dipstick into the
tube and rest the oil fill cap on the
tube. Do not thread the cap onto the
tube when taking reading. Keep oil
at “FULL" line on dipstick. Tighten cap
onto the tube securely when finished.

Advertising