BLADE PARALLEL TO THE MITER GAUGE

GROOVE (FIG. R,S)

A

WARNING

This adjustment was made at the factory, but it
should be rechecked and adjusted if necessary.

A

WARNING

To prevent personal injury:

Always disconnect plug from the power source
when making any adjustments.

This adjustment must be correct or kickback
could result in a serious injury and aocurate outs
can not be made.

1. Remove the yellow switch key and unplug the saw,

2. Move the blade guard out of the way.

3. Raise the blade to the highest position and set at

the 0° angle (90° straight up).

4. Select and mark, with a felt tip marker, a blade

tooth having a “right set”. Angle and positioning
this tooth 1/2” above the table at the front of the
saw.

5. Place the combination square base (1) into the

right side miter gauge groove (2). (Fig. R)

6. Adjust the rule so it touches the front marked tooth

and lock ruler so it holds its position in the square
assembly.

7. Rotate the blade bringing the marked tooth to the

rear and about 1/2 inch above the blade.

8. Carefully slide the combination square to the rear

until the ruler touches the marked tooth.

9. If the ruler touches the marked tooth at the front

and rear position, no adjustment is needed at this
time. If not, perform the adjustment procedure
described in next section.

Fig. R

Additional blade adjustments (Fig. S)

NOTE; The adjusting nuts are 8mm.

The adjusting mechanism is located above the blade

height adjusting hand wheel under the tabletop. If

the front and rear measurements are not the same,
adjust the alignment by the mechanism as follows:

If the blade is partial to right side:

1. Loosen the two nuts (1) and the right side screw ,

then adjust the left side screw .

2. Tighten the nuts (1) and the right screw and

remeasure, as described in steps 4 to 9 in the
prior section.

If the blade is partial to left side:

3. Loosen the two nuts (1) and the left side screw ,

then adjust the right screw to its position .

4. Tighten the nuts (1) and the left screw and

remeasure, as described in steps 4 to 9 in the
prior section.

5. Recheck blade clearance making sure that the

blade does not hit the table insert or other parts

when at the 90° and 45° settings.

Fig. S

15