Before running engine, clean muffler area to remove all

combustible debris.

Clean and Replace Spark Plug

Change the spark plug every 100 hours of operation or
once each year, whichever comes first. This will help

your engine to start easier and run better.

SERVICE ADJUSTMENT

Carburetor

The carburetor of your generator is pre-set at the factory.

The carburetor should not be tampered with, if your gen­

erator is used at an altitude in excess of 4000 feet perfor­
mance may be affected. If so consult with your nearest

Sears Service Center regarding high altitude set changes.

Go¥ernor

Your engine governor maintains the constant operating

speed of your generator. DO NOT tamper with the engine

governor which is factory set for proper engine speed.

Over-speeding your engine above factory high speed set­

ting can be dangerous and could possibly cause personal

injury or property damage. If you believe the engine is run­

ning too fast or slow, take your generator to a Authorized

Sears Service Center for repair and adjustment.

CAUTION: Low engine speeds impose a heavy load
on the engine and when sufficient power is not avail­

able the engine life could be shorten.

STORAG

If you are going to store your generator for more than 30

days, use the following information as a guide to prepare

the generator for storage.

STORAGE INSTRUCTIONS

CAUTION: Never store generator with fuel in the

tank indoors or in enclosed, poorly ventilated areas,

where fumes can reach an open flame, spark or pilot

light as on a furnace, water heater, clothes dryer or

other gas appliances.

Engine Preparation

• Add fuel stabilizer to fuel tank to minimize the

formation of fuel gum deposits during storage.

» Run engine at least 10 minutes after adding stabilizer

to allow it to enter the fuel system.

• Next shut off engine.

• Disconnect the spark plug wire and remove the

spark plug.

• Add one teaspoon of oil through the spark plug hole.

® Place rag over spark plug hole and pull the recoil a

few times to lubricate the combustion chamber.

Replace the spark plug, but do not connect the spark

plug wire.

NOTE: if a fuel stabilizer is not used, all gasoline must

be drained from the tank and carburetor to prevent gum

deposits from forming on these parts and causing

possible malfunction of the engine.

Generator

» Clean the generator as outlined on Page 14 {Generator

Maintenance)

• Check that cooling air slots and openings on generator

are open and unobstructed.