Calibration – Cooper Hand Tools LUFKIN LCL4 User Manual

Page 13

Advertising
background image

Page 13

x

x

A2

B2

4-5m

15cm

Surface 1

Surface 2

Figure 2

CALIBRATION

To check plumb:

Choose a door jamb

with a minimum of 2.5

metres clearance on

each side of the door.

Turn on the LCL4 to “auto level” setting.

With your laser at point “A” (figure 3),

make two marks on the floor.

Make the first mark at 2.5 metres from

point “A” centred on the door header

above. Mark this point “B”.

Make a second mark 5 metres from point “A”. Make this point “C”.

Without moving the laser, make a third mark on the door header. Make this point “D”.

Now move the laser to point “C”. EXACTLY align the beam with point “B”. Notice where the

beam falls at point “D”. If it is within 4mm of point “D”.

The laser is in calibration.

A

B

C

D

Figure 3

Advertising