Operation – Cooper Hand Tools LUFKIN LCL4 User Manual

Page 8

Advertising
background image

Page 8

OPERATION

Horizontal, Vertical, Plumb & Cross Line Options

The LCL4 has three line options, accessible by using the line options button located on

the top of the instrument. If the unit has been turned on, the plumb up and down beams

will always be on. Use the line option button to cycle through the level (horizontal), plumb

(vertical) or cross line modes, as shown below.

Auto-Off Feature

A battery saving Auto-Off feature has been incorporated into the LCL4. It will shut the device

off automatically after 60 minutes unless overridden. To disable the Auto-Off feature press

and hold the line options button when turning the unit on. The green LED will flash twice per

second to indicate the Auto-Off feature has been disabled.

Low Battery Indicator

When the battery charge becomes low, the red LED will flash twice per second. Note: the

LCL4 can be used for up to one hour during low battery indication before it will turn off

completely.

Pulse Mode

Pressing the pulse mode button, will place the unit into pulse mode so that it can work

with optional laser detector. Pressing the button again, returns to non-pulse mode. In pulse

mode, the Pulse Mode LED will be on.

Default line
Horizontal & Plumb up and down line

Cross & Plumb up and down line

Cross & Plumb up and down line locked

Vertical & Plumb up and down line

Press 2x

Press 1x