Flexible Pump Coupler

The flexible pump coupler is a nylon “spider” insert, located

between the pump and the engine shaft. Over time, the coupler

will harden and deteriorate. If you detect vibration or noise

coming from the area between the engine and the pump contact

an authorized service dealer. If the coupler fails completely, you

will experience a loss of power.

Beam

Lubricate both sides of the beam (where it comes into contact with

the splitting wedge), before each use, with engine oil.

Off-Season Storage

If the log splitter will not be used for more than 30 days, prepare

it for storage as follows:

WARNING!

Never store the machine with fuel in

the fuel tank inside of building where fumes may

reach an open flame or spark, or where ignition

sources are present such as hot water and space

heaters, furnaces, clothes dryers, stoves, electric

motors, etc.

Refer to the Engine Operator’s manual packed with your

1.

log splitter for information on the off-season storage of the

engine.
Clean the log splitter thoroughly.

2.

NOTE: The use of pressure washers or a garden hose to

clean the splitter is not recommended. They may cause

damage to the bearings or the engine. The use of water will

result in a shortened life and reduce serviceability.
Wipe the machine with an oiled rag to prevent rust,

3.

especially on the wedge and the beam.
Store the log splitter in a clean, dry area. Do not store it

4.

next to corrosive materials, such as fertilizer.
NOTE: If storing in an unventilated or metal storage shed,

be certain to rustproof the equipment by coating it with a

light oil or silicone.

If necessary Refill the reservoir within range marked on the

11.

dipstick. See Fig. 6-3.

Extend and retract the wedge 12 complete cycles to remove

12.

trapped air in the system (the system is “self-bleeding”).

WARNING! Much of the original fluid has been drawn into

the cylinder and hoses. Make certain to refill the reservoir

to prevent damage to the hydraulic pump. Failure to refill
the tank will void the log splitter’s warranty.

NOTE: Some fluid may overflow from the vent plug as the system

builds heat and the fluid expands and seeks a balanced level. Do

not operate the log splitter without the proper amount of fluid in

the reservoir tank.

Maintain the fluid level within the range specified on the

13.

dipstick at all times. When checking the fluid, always make

sure to tighten the dipstick until the top of the threads are

flush with the top of the pipe.
NOTE: Always dispose of any used hydraulic fluid and

engine oil at approved recycling centers only.
Contaminants in the fluid may damage the hydraulic

14.

components. Flushing the reservoir tank and hoses with

kerosene whenever service is performed on the tank,

hydraulic pump or valve is recommended. Contact an

authorized service dealer.

Hose Clamps

Check the clamps on the return hose before each use and check

the clamps on the suction hose once a season.

Hydraulic Filter

Change the hydraulic filter every 50 hours of operation. Use only

a 10 micron hydraulic filter. Order part number 723-0405.

Dipstick

MIN

Hydraulic Fluid

Only

MAX

Figure 6-3