Additional features – LG L8010ER User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Operating Instructions

Additional Features

I

Drain Pipe

In humid weather, excess water may

cause the Base Pan to overflow. To
drain the water, remove the Drain Cap
and secure the Drain Pipe to the rear

hole of the Base Pan.
Press the drain pipe into the hole by
pushing down and away from the fins

to avoid injury.

This air conditioner is equipped with a
slingerfan. (See drawing, below.)
The fan has an outer ring that runs in
the water that collects in the base pan

if it gets deep. That condensate is then
picked up by the fan and expelled

through the condenser, making the air
conditioner more efficient.

Drain Pipe—I

Drain Cap

Ring

CAUTION: Be careful when inserting the drain pipe. Push away from

, the sharp fin area to avoid siipping injuring yourself.

Removal From Window

Turn the air conditioner off, disconnect the power cord, remove the L bracket, the
screws and Support Bracket installed through the top and bottom of the guide

panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip

on the air conditioner, raise the sash, and carefully tilt the air conditioner backward,
draining any condensate. Lift the air conditioner from the window and remove the
sash seal from between the windows.

Be sure to drain ALL condensate from the air conditioner. If you don't, it could run

out while you carry the unit, making a mess and creating a slipping hazard. This
simple step will save you much cleaning and make a safer work environment.

20 Room Air Conditioner

Advertising