The air conditioner may be operating abnormaiiywhen:

Probiem

1

Possibie Causes

|

What To Do

1

■ The air conditioner is

unplugged.

Make sure the air conditioner plug is
pushed completely into the outlet.

Air

■ The fuse is blown/circuit

breaker is tripped.

Check the house fuse/circuit
breaker box and replace the fuse

or reset the breaker.

conditioner

does not
start

■ Power failure.

If power failure occurs, turn the
mode control to Off (Mechanical

Type).

When power is restored, wait 3

minutes to restart the air conditioner

to prevent tripping of the compressor

overload.

■ The current interrupter

device is tripped.

Press the RESET button located

on the power cord

plug. If the RESET button will not

stay engaged,
discontinue use of the air
conditioner and contact a qualified
service technician.

■ Airflow is restricted.

Make sure there are no curtains,

blinds, or furniture blocking the

front of the air conditioner.

Air

conditioner

does not

cooi as it

shouid

■ The thermostat may not

be set high enough.

Turn the knob to a higher number

The highest setting provides,

maximum cooling.

■ The air filter is dirty.

Clean the filter at least every 2

weeks.

See the care and Maintenance

section.

■ The room may have been

hot.

When the air conditioner is first

turned on, you need to allow time
for the room to cool down.

■ Cold air is escaping.

Check for open furnace floor
registers and cold air returns.

■ Cooling coils have iced up.

See Air Conditioner Freezing Up
below.

Air

conditioner

freezing up

■ Ice blocks the air flow and

stops the air conditioner

from cooling the room.

Set the mode control at High Fan

or High Cool with thermostat at 1
or 2.

* You can refer to the Energy Star program in detail at www.energystar.gov.