7 - Appendix

Word Clock In/Out

E-MU Digital Audio System

99

Word Clock In: Receives word clock (sample clock) from another digital device such as
a digital video deck, digital recorder or digital mixer.

Word Clock Out: Sends word clock (sample clock) to another digital recorder. Word
clock is always output, whether it is generated by the internal clock or passed through
from the word clock input.

75 On/Off: Termination for the word clock input can be switched on or off in the
Sync Card menu of the PatchMix DSP application. Normally word clock termination
should be left on. If you have problems with a weak word clock signal, try turning termi-
nation off. See

Word Clock Termination

.

The diagram below shows the proper way to connect and terminate a serial word clock
chain. Using a BNC “T” connector ensures that word clock is precisely in phase for both
devices. The middle device has termination turned Off and the last device in the word
clock chain has termination turned On.

House Sync

Generator

Digital

Device 1

Digital

Device 2

Digital

Device 3

Digital

Device 4

A master word clock generator is preferable for larger digital setups.

Wo

rd
Clock

Word Clock

Word Clock Termination ON

Word Clock Termination OFF

SYNC CARD

E-MU 1010 CARD

IN

Digital Mixer

ADAT Optical
or AES Digital

ADOCK

IN

T - connector

AES

ADAT Optical

This diagram shows the proper way to connect word clock if you don’t have a multi-output
word clock generator. The last device in a Word Clock chain should have Termination ON.