Section 319-29E-202

3

2.

APPLICATION ENGINEERING

The 3192–9E is ideally suited for use in provisioning T1 High Capacity Digital Service (HCDS) from lightwave-fed
building Remote Terminals located at customer premise locations. See Figure 2 for a typical application. The
3192–9E, used as adjunct equipment to the Lightwave Multiplexer, provides transmission loopback for mainte-
nance activities. In addition, the 3192–9E can be optioned to provide a 60mA constant current power source to-
wards the network interface, which can be used to power the customers’ Channel Service Unit (CSU). This ser-
vice arrangement is typical in MPOP (Minimum Point Of Presence) applications.

The 3192–9E is intended to be co-located with the lightwave transport equipment and serves to extend the nor-
mal DSX range of that equipment. The 3192–9E provides a fixed DSX pre-equalizer for 0 to 110 feet of cable. In
the transmit direction the unit provides variable pads for level coordination toward the CPE. The 3192–9E can
accommodate up to 21dB of cable loss between the customer’s CSU and the 3192–9E.

Figure 3 shows a typical 3192–9E application with associated transmission levels.

Note:

Range is limited to maximum cable loss of 21.0db. See table below for maximum cable length at
various cable gauges.

–1.5dB

–1.5 To

–22.5dB

Pre
Equalizer

0.0

DSX–1

Lightwave

Multiplexer

3192–9E Powering T1 NIU

0.0

T1 CSU

LBO

LEC Equipment

CPE Equipment

Customer

Wiring

Maximum

Loss 21.0dB

(See NOTE)

–1.5dB

-1.5 To

-22.5dB

Customer

Network

Interface

Note:

Signal Levels Referenced

To 3V Base-To-Peak

CABLE @ 130 F

AERIAL - PIC

MAXIMUM

LENGTH -KF

TOTAL DCR

@ MAXIMUM

REFERENCE

LOSS - dB/KF

REFERENCE

LOSS - OHMS/

KF

REFERENCE

MAXIMUM

LOSS

22 GA-CU

4.29 KF

78 OHMS

4.9 dB/KF

18.3 OHMS

21.0dB

24 GA-CU

3.44 KF

100 OHMS

6.1 dB/KF

29.2 OHMS

21.0dB

26 GA-CU

2.56 KF

119 OHMS

8.2 dB/KF

46.7 OHMS

21.0dB

Figure 3. 3192–9E T1 Powering NIU Typical Configuration

2.1

Customer Interface Powering Options

The 3192–9E provides three, switch-selectable, CI (Customer Interface) side power modes: line powering, seal-
ing current, and looped simplex. See Part 6 for more information.

2.2

System Power Engineering

The 3192–9E generates all necessary voltages for its operation from a –48V (nominal) battery input source. The
3192–9E contains an internal high efficiency DC–DC converter to minimize input current, and consequently, maxi-
mize battery reserve time in the remote terminal assembly.