Charles Industries 31929E User Manual

Page 6

Advertising
background image

Section 319–29E–202

6

S3

1

2

S4

DISABLE

A

I

S

S1

PWR

7.5 7.5

1

2

O

N

LP

SC

S2

LOS

ALM

R

C

V

X

M

T

R

P

T
M

O

N

R

P

T
M

O

N

WESCOM

PWRG

T1

NIU

3192-9E

91-31929E

0.6V

ISS. 2

FA

ESF

NET

LOS

LB

CI

LOS

MLB

r

Figure 6. 3192–9E Front Panel Features and Options Location

Table 2. 3192–9E Front Panel Options Description

Feature/Option

Location

Description

Function

FA (Fuse Alarm)

Front Panel

Red LED

Indicates that the internal fuse on the 3192-9E has opened. The internal fuse is
not field replaceable.

NET LOS (Loss of
Signal)

Front Panel

Red LED

Continuous: Indicates LOS (Loss Of Signal) from the network side.
Flash: Indicates receipt of AIS from the network side.

CI LOS (Loss of
Signal)

Front Panel

Red LED

Continuous: Indicates loss of signal from the customer interface side.

Flash: Indicates sending of AIS to the network side.

LB (Loopback)

Front Panel

Amber LED

Indicates that the unit is in the Loopback State.

ESF (Extended
Superframe)

Front Panel

Green LED

Indicates ESF Framed signal from the network.

RCV RPT

Front Panel

Bantam Jack

Isolates the DSX allowing access to repeater RCV DSX (OUT).

RCV MON

Front Panel

Bantam Jack

RCV DSX (OUT) monitor jack.

+ Test Pins

Front Panel

Pin Jack

Used for measuring span current and voltage.

– Test Pins

Front Panel

Pin Jack

Used for measuring span current and voltage.

XMT RPT

Front Panel

Bantam Jack

Isolates the DSX, allowing access to repeater XMT DSX (IN).

XMT MON

Front Panel

Bantam Jack

XMT DSX (IN) monitor jack.

S1

PC Board

3 Position Slide
Switch

3Ćposition switch to select either PWR (line powering), SC (Sealing Current) or

LP (Looped Simplex) CI side power modes.

S2

Front Panel

Front Panel Push-
button Switch

S2 is the recessed front panel MLB (Manual Loopback) pushbutton switch to

manually activate or deactivate loopback.

S3

PC Board

2 Section Dip
Switch

S3–1 enables or disables a LOS condition alarm detected by CI side.
S3–2 enables or disables the operation of the Customer Receive Side AIS gen-
erator

.

S4

PC Board

2 Section Switch

Adjusts the transmit pad, allowing a transmit path loss of 0, 7.5 or 15 dB.

Advertising