Salter Brecknell 650 User Manual

Page 38

Advertising
background image

38

Figure B-5: Pin assignments for the COM2 serial port connector

SCALE

COMPUTER

2 RXD

TXD 3

S. GND 5

5 S. GND

DSUB9M

DSUB9F

3 TXD

RXD 2

4
6
8

DTR
DSR
CTS

SCALE

SCANNER

2 TXD

RXD 2

S. GND 5

5 S. GND

DSUB9M

DSUB9M

FIGURE B-6: Cable Diagram for Scale to Computer

FIGURE B-7: Cable Diagram for Scale to Scanner

B.2.2

FULL DUPLEX MODES FOR COM2

B.2.2.1

DEMAND MODE

The Demand mode allows control from a host device, usually a PC, and can be activated

by pressing the Print soft key. Figure B-8 shows the serial data format for the

Demand Mode. Table B-1 shows the recognized host commands.

<STX> <POL> xxxxx.xx

<LB/KG>

<GR/NT> <CR> <LF>

Polarity:

<SP> = Positive

"–" = Negative

Weight Data

Units:

lb = pound

kg = kilogram

Gross/Net:

GR = Gross

NT = Net

Start

Transmission

Carriage

Return

Line

Feed

<SP>

<SP>

Space

Space

pc = pieces

FIGURE B-8. Consolidated Controls Demand Mode