Figure B-5: Pin assignments for the COM2 serial port connector
SCALE
COMPUTER
2 RXD
TXD 3
S. GND 5
5 S. GND
DSUB9M
DSUB9F
3 TXD
RXD 2
4
6
8
DTR
DSR
CTS
SCALE
SCANNER
2 TXD
RXD 2
S. GND 5
5 S. GND
DSUB9M
DSUB9M
FIGURE B-6: Cable Diagram for Scale to Computer
FIGURE B-7: Cable Diagram for Scale to Scanner
B.2.2
FULL DUPLEX MODES FOR COM2
B.2.2.1
DEMAND MODE
The Demand mode allows control from a host device, usually a PC, and can be activated
by pressing the Print soft key. Figure B-8 shows the serial data format for the
Demand Mode. Table B-1 shows the recognized host commands.
<STX> <POL> xxxxx.xx
<LB/KG>
<GR/NT> <CR> <LF>
Polarity:
<SP> = Positive
"–" = Negative
Weight Data
Units:
lb = pound
kg = kilogram
Gross/Net:
GR = Gross
NT = Net
Start
Transmission
Carriage
Return
Line
Feed
<SP>
<SP>
Space
Space
pc = pieces
FIGURE B-8. Consolidated Controls Demand Mode