17.2 Causes and rectification of faults
In the event of a fault, an error code will appear in the display; it describes the
cause of the fault.
The following table assists in localizing and rectifying minor faults.
Fault
Possible Cause
To Rectify
--- ----
Waiting status
► Place a suitable pot/pan onto the induction
cooking field. The plate will work as usual
E01
Electronic control of low
voltage. (<160V)
► Make sure the appliance is connected to
the voltage indicated
E02
► Electronic control of excess
voltage (>270V)
► Make sure the appliance is connected to
the voltage indicated on the rating label.
E03
IGBT open or short circuit.
► Please send back to customer service.
E05
Overheating protection on
power mode (>150°C)
► Eliminate the course of overheating. Once
the cooktop has cooled, the appliance can
be put into operation again.
E06
Temperature sensor open or
short circuit
► The temperature sensor underneath the
glass ceramic plate is defective. Please
send back to customer serivce.
E07
Overheating protection on
TEMP. mode (>240°C)
► Eliminate the course of overheating. Once
the cooktop has cooled, the appliance can
be put into operation again.
E08
Temperature sensor
malfunction
► Please send back to customer service.
Please note
► If error messages continue to be displayed after an extended waiting period or after
restarting the appliance, then it must be sent to Customer Service to be examined.
► If you are unable to solve the problem with the steps shown above, please contact