O.o.o.o, Key pad functions, Operating instructions – CDI Torque COMPUTORQ II Electronic Torque Wrench User Manual

Page 3: Ooo.o o, Ooo.o 2

Advertising
background image

1

CLEAR

ZERO

dNm cmkg in-oz in-lb ft-lb

LO BAT

TRACK

PEAK

RECALL

SETUP

AUTO POWER OFF

STORE

SEND

2

3

4

COMPUTORQ II

OVER

o.o.o.o

000

000

6.00’

6.00’

6.00’

1

o.o.o.o

1

CLEAR

ZERO

STORE

SEND

2

RECALL

SETUP

3

4

STORE

SEND

2

RECALL

SETUP

3

4

TRACK

ooo.o

o

TRACK

2.ooo

TRACK

ooo.o

2

2”

BATTERY

BATTERY

OFF ON

0 0 0 1

LINE FEED

CARRIAGE

RETURN

UNITS

BLANK

VALUE

SIGN

BLANK

SEQUENCE #

1 2 3 , 4 5

I N - L B

CR LF

+

A
B
C
D
E
F
G
H
I

J
K
L
M
N
O
P
Q
R
S
T
U
V

INSTRUCTIONS LEGEND

LIGHT ON
BUZZER SOUNDS

INPUTTING THE LENGTH OF THE ADAPTOR

ACCEPTED

GO BACK TO MAIN MENU

CENTER OF SQUARE DRIVE TO

CENTER OF THE OPEN END.

BOX END OR FLARE NUT DRIVES

PRESS
PRESS + HOLD

UNITL

BUZZER SOUNDS

kEY PAd FUNcTIONS

ANALOG BAR GRAPH
SUPER TWIST LIqUID CRYSTAL DISPLAY
7 TORQUE UNITS (Ft.Lb., In.Lb., In.Oz., Nm, dNm,
MKG, CmKG
GREEN “GO” LIMIT LED
POWER ON/OFF
CLEAR LCD DISPLAY
ZERO TARE
ENTER (ACCEPT INFORMATION)
RECALL TORqUE DATA STORED IN MEMORY
OVER TORqUE “WARNING”
SPECIFIC TORqUE NUMBER IN MEMORY BEING
RECALLED AND SHOWN ON LCD
NUMBER OF TORqUE VALUES IN MEMORY
LOW BATTERY INDICATION
TRACK MODE
PEAK HOLD MODE
RED “OVER TORqUE” LIMIT LED
SCROLL UP (INCREASE VALUE DURING SET-UP)
STORE DATA TO WRENCH
SEND DATA TO COMPUTER/DATA LOGGER/
PRINTER
SHIFT TO NEXT FLASHING DIGIT (DURING SET-UP)
SET-UP PARAMETERS
(TOLERANCE LIMIT/TORqUE UNIT)
AUDIO BUZZER

OPERATING INSTRUcTIONS

Please Note: There is an “off-on” slide switch located on
the right side of the wrench The wrench is shipped from
the factoiy with the switch in the “off” position. Before
use, slide the switch up or “on” Place the switch in the
“off” position only if the wrench is to be stored or not
used for a period of time. Otherwise, leave the switch in
the “on” position.

ELECTRONIC WRENCH SETUP

TO TURN WRENCH “ON”

Press Button #1 (on/off).
Slide battery selector switch “Up” (on) or press Button
#1 (on/off) if slide switch is already in
the “Up” position.
The red and green lights will flash.
Zeros will flash and then be displayed on
the LCD along with the unit of torque measure.
The wrench is ready to use.
NOTE: If button #1 is pressed

and held when first

turning the wrench “on”, the torque range capacity
and current software version of program will be
displayed. When first turning the wrench
on (sliding the switch “up”), the LCD will
flash “data good” then flash all zeros.

TO CHANGE MODE OF OPERATION: “TRACK” OR

“PEAK”

1. Press Button #4 (set-up) one time.

Either “Track” or “Peak” will be flashing.

2. To change the mode, press Button #2 (store/send).

Continued pressing of Button #2 (store/send) will
toggle between “Track” and “Peak”

3. Press Button #3 (recall) to accept the

desired “flashing” mode change into
wrench memory.

• TO CHANGE UNIT OF TORQUE MEASURE: In.lb., In.oz.,

NM, dNM, MKG, CmKG, ft.lb.

1. Press Button #4 (set-up) two times.

The unit of measure will flash on the display.

2. To change the unit of measure, press

Button #2 (store/send). Continue
pressing Button #2 (store/send) until
the unit of measure desired is blinking
on the LCD.

3. Press Button #3 (recall) to accept this change into the

wrench memory.

000.0

171.5

000.0

171.5

000.0

171.5

000.0

171.5

000.0

171.5

A
B
C

D
E
F
G
H
I
J
K

L
M
N
O
P
q
R
S

T
U

V

Advertising