4.2 Map: Copy

To copy a map, first select Copy from the Map Menu. The following Copy/Lock Menu will be displayed:


Copy 1 2 3 4 5

Q

Lock L U U U U Q

Copy 1-5

Selects which map to copy the current map TO

Lock

L = Locked, U = Unlocked

Q

Quits this menu

This screen is used to save the CURRENT fuel adjustment map TO one of five available map locations. The map
that is being copied TO must be Unlocked – otherwise a message will be displayed telling you that the map you
selected cannot be overwritten.

Note: When a map is copied, the Control Box will load the map copied TO to be the new current map.

Use the Up/Down and Left/Right Arrow keys to move the cursor to the map number you want to copy TO and
press “SEL”. The following confirmation message will be displayed:

Overwrite Map A

With Map B? Y

N

A” represents the map copied TO and “B” represents the current map to be copied FROM. If this is exactly what
you intend, use the Left Arrow to underscore “Y” and press “SEL”. Then the current map will be loaded into the
selected map number, the selected map number will become the current map, and the Control Box will return to the
Main Menu.

To quickly Lock or Unlock maps, move the cursor down to the Lock row, place the cursor under the L or U by the
desired map number, and press “SEL” to change a U (Unlocked) to an L (Locked) or vice versa.

Select Q to Quit and return to the Main Menu.


4.3 Map – Lock and ULock

Either Lock or ULock (UnLock) can be selected from the Map Menu to quickly lock or unlock the current map.
Move the cursor to the desired selection and press “SEL”. The box will return to the Main Menu and the current
map will be locked or unlocked when SEL is pressed.


4.4 Map – StUp (SetUp)

Select “StUp” to change the N2O regulator Mode. Use the Up/Down arrows to change between: “ADJ” if an
adjustable nitrous regulator is used, “FIX” if a fixed nitrous regulator is used, or “NON” if nitrous is non-regulated.
Press “Sel” to go back to the MAP Menu.

N2O Regltr Mode:

ADJ